Ayesha Automation and Equipment Supplier

Website: https://ayeshaautomation.com

GC Analyzers (Gas Chromatography), Fatty Acid Analyzer (YL6500 GC)

GC Analyzers (Gas Chromatography), Fatty Acid Analyzer (YL6500 GC)

Features

Brand YOUNG IN Chromass
Origin Korea
Category Food Engineering, Chromatography, Lab Equipment
Price Call for Price

Short Description

Model: Fatty Acid Analyzer (YL6500 GC)

  • Accurate sample preparation method support
  • Analysis method setup with powerful & easy to use Chromatography Data System
  • Customized application support with recommended columns and consumables
  • Superior cost effectiveness with optimized analysis efficiency
  • Low maintenance cost and long term stability

Specifications

(1) Sample

Lipolysis: 

  • Sample 25mg Add 0.5N NaOH methanol solution 1.5 ml and mix
  • Heat at 100 °C for 5 min
  • Cool down to 30-40 °C 

Fatty Acids Esterification:

  • Add 14 % Trifluoroborane methanol solution 2 ml and mix
  • Heat at 100 °C for 2 min
  • Cool down to 30-40 °C, add 1 ml of hexane (or heptane) and stir it for 30 sec.
  • Add 5 ml of saturated NaCl solution and stir
  • Separate layers at the ambient temperature
  • Use an upper layer (Hexane or hexane layer) as a sample

(2) Standard 

  • Fatty acids in edible oils –14 kinds of Fatty acid methyl ester mix
  • Trans fatty acids- 37 kinds of Fatty acid methyl ester mix
  • cis, trans isomer standard of 18:2, 18:3
  • Omega 3 fatty acids – DHA, EPA standard

Application:

  • Fatty acids in edible oils
  • Trans fatty acids
  • Omega 3 fatty acids (DHA, EPA)

Description

Fatty Acid Analyzer (YL6500 GC)
Fatty Acid Analyzer is suitable to analyze various fatty acids and provide all the solution from preparation of sample to analysis.

In the food industry, the quality management for fat containing products is conducted by analyzing esterified fatty acids to determine the ratio of saturated and unsaturated fatty acids in fat.

However, determining the fatty acid composition of a product may be difficult because foods can contain a complex mixture of saturated, monounsaturated, and polyunsaturated fatty acids, each with a variety of carbon chain lengths.

It’s very important to set an optimal oven program because the polar or moderately polar capillary columns used in this analysis have low temperature limit.

The recommended column for the analysis of fatty acids in edible oils is polar capillary columns such as Omegawax or Innowax, and for trans fatty acids is moderately polar capillary columns such as HP-23 or SP-2560 to separate cis/trans isomers. The order of peaks must be identified first for the eluted peaks of fatty acids are different in the use of polar or moderately polar capillary columns.

Fatty Acid Analyzer is suitable to analyze various fatty acids and provide all the solution from preparation of sample to analysis.