Biohazard Safety Cabinet Class II Type A2 Ultraviolet Output: 7.5 W

Out of stock

Model: JSCB-900SB 

  • Safety Class :BSC Class II Type A2
  • Air flow type: 70% re-circulation / 30% exhaust
  • Down-Flow: 0.3 m/sec
  • In-Flow :0.5 m/sec
  • Filtration Efficiency: HEPA filter 99.993~99.995 % for particles > 0.3 um
  • (Nominal): ULPA filter 99.999 % for particles > 0.12 um
  • Noise Level: < 65 dB
  • Work Light: 1510 Lux
  • Type of Work Light: LED 20 watt x 2 ea
  • Germicidal UV Lamp 253.7 nm: 30 Watt
  • Ultraviolet Output :13.4 W
BDT 1,050,000.00

Controller

  • Integrated Digital microprocessor control system with graphic LCD display
  • Fan ON/OFF and 10-step adjustable air velocity
  • LED lamp ON/OFF
  • UV lamp ON/OFF
  • Adjustable UV sterilization timer
  • Elapsed time counter and alarm for HEPA filter replacement

Construction:

  • Durable epoxy powder coated metallic casing
  • Removable Stainless Steel 304 working plate

Performance

  • Biological Safety Level Class II Type A2 design provides a higher level of personnel, product and cross contamination protection by keep filtrate airborne particles from the air stream
  • Inflow moves from the room air is drawn into the inlet grille at the work access opening and pass through a negative pressure plenum to blower creates HEPA filtered downward laminar air stream over the work area
  • Approximately 70% of the HEPA-filtered air is re-circulated through the cabinet into the work zone, while 30% passes through an exhaust HEPA filter and is discharged into the laboratory room air
  • Aluminum Frame Mini-pleated HEPA filters with nominal filtration efficiency of 99.993% ~ 99.995% for airborne particles larger than 0.3 um
  • Optional ULPA filter had higher filtration efficiency of 99.999% for airborne particles larger than 0.12 um

Convenience:

  • Ergonomic arm rest and 3 degree slanted front glass window
  • Removable working zone plate for easy cleaning and decontamination
  • Front service access panel for comfortable maintenance
  • The front door can also be closed fully to keep the cabinet interior clean during non-use period as well as to prevent exposure to UV radiation during sterilization
  • Epoxy powder coated SPCC exterior for durability
  • Silent and vibration free blower fan motor for comfortable working environment
  • LED lamp working light
  • 253 nm Germicidal UV lamp on working zone
  • Supplied with Base Stand with caster

Safety

  • UV Lamp CUT-OFF In case of fluorescent lamp turned on
  • TOTAL USING TIME LOG
  • HEAP Filter replacement alarm
  • OVER CURRENT CUT-OFF : Fuse

Performance Data:
Safety Class :BSC Class II Type A2
Air flow type: 70% re-circulation / 30% exhaust
Down-Flow:  0.3 m/sec
In-Flow :0.5 m/sec
Filtration Efficiency: HEPA filter 99.993~99.995 % for particles > 0.3 um
(Nominal): ULPA filter 99.999 % for particles > 0.12 um
Noise Level: < 65 dB
Work Light: 1510 Lux
Type of Work Light: LED 20 watt x 2 ea
Germicidal UV Lamp 253.7 nm: 30 Watt
Ultraviolet Output :13.4 W

Dimension Data:
Working Width: 1790 mm (6 ft)
Int. Dims. (W x D x H mm): 1790 x 550 x 585
Ext. Dims. (W x D x H mm) w/o stand: 1860 x 800 x 1290
Ext. Dims. (W x D x H mm) /w stand: 1860 x 800 x 1970

Safety Device:
Automatic UV Lamp turn off on door open
HEPA filter replacement alarm

Material Data:
Working Plate: Removable Stainless steel 304 (AISI 304)
Body: SPCC /w epoxy powder coating
Front sash door: Tempered safety glass door

Utility & Accessories:
Working LED Lamp: 20 watt x 2 ea
Germicidal UV lamp: 40 watt
Nominal power: 375 Watt   1.7 amp
Power receptacle for 220 V European cord x 2 ea
Gas cock x 2 ea

Usable Condition:
Temp. & Humidity: 5oC – 40 oC, < 80% RH
Electric: 220±10% VAC 50/60Hz 1-Phase | Plug config. | CEE 7/7 Schuko or BS-1363
Net Weight: 267.0 kg

Warranty: 01 (One) year warranty from the date of installation.
Installation & Training: Free installation, operation & maintenance training will be provided at your laboratory site.